P0140 – O2 Sensor Circuit No Activity Detected Bank 1 Sensor 2
The oxygen sensor after the catalytic converter on bank 1 (sensor 2) is a switching sensor (about 0.1–0.9 V) used for converter monitoring and fine mixture trim. P0140 means the sensor produces no voltage of its own and the control module only sees its own reference (bias) voltage. GM's V6 sets it when the signal sits at 401–548 mV or the sensor's internal resistance exceeds 40 kΩ when it should be hot; newer GM systems apply 1900 mV and read above 1700 mV as an open circuit. Two trips. Ford reports 'no activity' under P0136 instead. A cold sensor with a failed heater can also cause it. When it fails, the control module stops the downstream trim and cannot evaluate the converter; there is no limp mode.
Possible causes
- Signal or ground wire open, connector off or corroded
- Sensor heater failed, sensor never becomes active
- Sensor worn out (no longer produces voltage)
- Control module input faulty
Possible symptoms
- Check engine light on (usually after two drive cycles)
- Catalyst monitor readiness not set
- Live data: sensor 2 stuck at about 450 mV (or 1.9 V)
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.