U067C – Lost Communication With Fan 3
Some engines need a third electric cooling fan, for instance for a charge-air or auxiliary radiator, and LIN lets each fan carry its own speed electronics. GM's 2025 diesel table 25OBDG04B uses U067C for cooling fan 3: the response frame CFM3_Rsp must be missing for at least 2,437.5 ms, the LIN channel enabled and battery voltage above 11 V; the code is Type B, so the MIL lights after two trips. While it is active GM suspends the fan 3 speed checks, P2CBB for running slower than modelled and P30F2/P30F3 for feedback out of range, the high limit being 4,000 rpm. On the engines of GM's 23OBDG07 and 24OBDG07 the same fan instead sets the GM-specific U112A on a third LIN line. Watch engine temperature under load.
Possible causes
- LIN wire to fan 3 chafed or open
- High-current supply, fuse or ground of fan 3 faulty
- Fan 3 controller electronics failed
- Fan connector corroded by road spray
Possible symptoms
- Check engine light after two trips
- High coolant or charge-air temperature at low speed or when towing
- Fan 3 silent or running constantly
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.