U0638 – Lost Communication With Hybrid/EV Electronics Coolant Temperature Sensor A

The coolant loop that serves the inverter and other high-voltage electronics needs its own temperature reading so the controller can size pump speed and decide when to derate. When sensor A on that loop is a bus node that sends its value digitally, for instance over LIN, the receiving controller notices when frames stop coming, and U0638 records that silence. No manufacturer documents this code publicly. CARB 13 CCR 1968.2 (e)(15.2.3)(B)(ii) requires every electronic input that serves inverter cooling to be checked like other input components, so a MIL is expected on hybrids. An analog sensor of the same position reports wiring faults through P0CEE to P0CF2 instead. Without a reading the system usually assumes a warm loop and limits electric power.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.