P2E85 – Battery Charger B Input Voltage Sensor Circuit Low
P2E85 means the input voltage signal of charger B sits too low, so the car sees little or no grid voltage while it expects AC. GM uses the code on its battery-electric models, from the 2017 Bolt EV to the Lyriq, Hummer EV, Blazer, Equinox and Silverado EV and BrightDrop vans, under the wording input voltage sensor circuit low voltage. Bulletin PIT6353 and TechLink March 2025 name a typical trigger: a DC-only NACS adapter used at a household outlet or AC wallbox, which routes the shared pins to the DC contacts, so no AC reaches the charger; P0D3F, P0F71 and on the Bolt P1EE6 may set with it. A 2026 TechLink lists P0E8B-11 beside it. With the right adapter the fault is gone; otherwise check inlet, wiring and the charger. Too high is P2E86.
Possible causes
- DC-only NACS adapter used on an AC charger
- Charging station or house circuit not delivering AC voltage
- Open or high-resistance AC path between inlet and charger B
- Sensing circuit inside charger B shorted to ground
Possible symptoms
- Vehicle does not charge on a Level 1 or Level 2 AC charger
- DC fast charging works without the adapter problem
- Further charger codes such as P0D3F or P0F71 stored
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.