P2C97 – Hybrid/EV Battery Disable Circuit Low
P2C97 is set when the high-voltage battery's wired disable input sits below its valid range, typically because the line is chafed through to body ground or the sending module pulls it low permanently. Whether low means shut down depends on the design. Where the line is active-low, a short to ground looks like a constant request to open the contactors, and the battery stays switched off; where a defined level is expected, the controller simply loses a trustworthy signal. The safety value of a hard-wired path is shown in Volkswagen patent US9586481B2, where it opens the contactor faster than a CAN message. No manufacturer documents P2C97 publicly. A shorted line should be traced section by section between the sender and the battery connector. CARB requires monitoring of hybrid components.
Possible causes
- Disable line chafed and shorted to ground
- Sending module holding the line low permanently
- Water in the connector creating a leakage path to ground
Possible symptoms
- High-voltage battery stays switched off, no ready mode
- High-voltage system warning
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.