P2B60 – Engine Coolant Flow Control Valve Position Sensor Circuit Range/Performance
P2B60 checks whether the valve actually goes where it is told. On GM's 3.0 L Duramax the code sets when the gap between desired and measured position exceeds 12 % in 160 of 200 samples, only with a steady command, closed-loop control active and no coolant or outside temperature sensor fault (Type B). For LM2 trucks and SUVs GM issued 20-NA-039 and 22-NA-082 (ECM software), PIP5764 (corroded terminals at the centre actuator connector) and PIP5791, which has the valve swept from 25 to 95 % with GDS2 and then relearned. Hyundai and Kia link P2B60 to the cleaning routine of the ITM module on 1.6 T-GDI engines (23-EE-002H, 24-FL-003H, Kia ELE 285) and fix it with software.
Possible causes
- Engine control software (GM 20-NA-039 / 22-NA-082, Hyundai/Kia ITM logic)
- Corroded terminals at the valve actuator connector (GM PIP5764)
- Valve sluggish or not learned, needs a relearn after test
- Valve does not follow commands although wiring is fine
Possible symptoms
- MIL on after two drives
- Engine temperature fluctuates or warms up slowly
- Often no driveability complaint beyond the warning lamp
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.