P2AA6 – EGR Cooler Bypass Control Circuit Driver Current/Temperature Too High Bank 2
P2AA6 is the bank 2 version of the bypass driver protection code. It only exists on engines with a separate EGR cooler and bypass actuator for the second cylinder bank, typically V engines whose banks each have their own exhaust manifold feeding EGR. The output stage for that actuator reports excessive current or junction heat and shuts itself off, which leaves the flap where it was. No manufacturer documents P2AA6 publicly. GM's diesel tables, which define the bank 1 code P2AA5 with a 170 °C driver limit and a Type B rating, show no bank 2 counterpart, as those engines use a single bypass. Causes match bank 1: a binding flap, a damaged motor or a partial short. Circuit faults on bank 2 are P248E, P2490 and P2491; a stuck flap is P24A6.
Possible causes
- Bank 2 bypass flap binding on soot or corrosion
- Internal fault in the bank 2 actuator motor
- Partial short in the bank 2 actuator wiring
- Faulty driver stage in the engine control module
Possible symptoms
- Malfunction indicator lamp on
- Bank 2 bypass flap stays in its last position
- Possible NOx or EGR temperature codes for bank 2
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.