P27A6 – Electric/Auxiliary Transmission Fluid Pump B Stuck On
P27A6 reports that auxiliary pump B keeps running, or keeps drawing current, while the controller has it switched off. Audi lists P27A600 in bulletin 34-17-25 for 2017 A4, A5 and A6 and 2018 Q5 models with 0CJ, 0CK and 0CL dual-clutch gearboxes; there the code may appear together with a rattle from the gear oil pump V553, which Audi traced to an assembly fault at the supplier and cures with a new pump. More generally, a pump that will not stop points to its own control electronics, a driver or relay that remains closed, or a control wire shorted to voltage, the case covered by P27A5. On pump A the same fault is P27A1. Apart from noise, a pump that never rests drains the 12 V battery and wears out early.
Possible causes
- Pump B module or electronics defective (e.g. Audi V553 supplier fault)
- Driver output or relay remains closed
- Control line shorted to battery voltage
Possible symptoms
- Pump noise or rattle from the gearbox area with the engine off
- Weak or flat 12 V battery
- Transmission warning stored
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.