P26E7 – Actuator Supply Voltage D Circuit/Open

Supply D is the fourth switched rail with which a control module powers a group of solenoids or other loads, after A (P0657), B (P2669) and C (P2684). P26E7 reports an open load on it. GM's 2023 and 2024 TCM tables assign the code to high-side output 8 and run the check only while the module shuts down: once the output is off and a low-side output on the same load is switched on, the load should pull the line down. If more than 40 % of battery voltage remains, the module keeps the finding in permanent memory and raises the code once it restarts, Type A. Ford's 2024 summary lists P26E7 as the open-load fault of high side driver 8 in the TR9070 dual-clutch gearbox. Everything fed from that rail is without power, so a substitute gear or limp mode is to be expected.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.