P2697 – Exhaust Aftertreatment Fuel Injector A Circuit/Open
Many heavy diesels do not raise exhaust temperature for filter regeneration by late in-cylinder injection, but spray diesel straight into the exhaust ahead of the oxidation catalyst through a separate doser, often called the seventh injector. P2697 means the solenoid that meters this fuel cannot be driven because its circuit is open. Volvo and Mack document it in their aftertreatment hydrocarbon injector (AHI) guide for US10 engines with 2013 OBD and later, as P2697 with failure type 13: the electric valve sits in the AHI dosing module, which moved onto the fuel filter housing from model year 2017, while the nozzle in the exhaust is purely hydraulic. The guide sends technicians to the module connector and harness. No dosing means no active regeneration, and soot builds up in the filter.
Possible causes
- Loose, corroded or damaged connector at the dosing module
- Harness to the dosing valve broken by heat or vibration
- Dosing valve coil inside the module burnt open
Possible symptoms
- Active particulate filter regeneration not possible
- Rising soot load, later derate
- MIL on
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.