P24A1 – Closed Loop Particulate Filter Regeneration Control At Limit - Temperature Too High

Here the regeneration loop has reduced its heat input as far as possible, but the temperature ahead of the filter still runs above target. GM lists P24A1 as the negative-deviation branch of the HC injector control check in steady regeneration, again a Type B fault counted over samples; the 2014 table calls it excessive hydrocarbon injector authority, and the 2018 table shows the check behind a calibration enable flag. Hino bulletin SB-22-007 names P24A1 and P24A2 on 2020 J08 conventional trucks fitted with a certain bubbler fuel filter, fixed by fitting a revised filter. Fuel leaking from a doser or injector, a sensor reading high or an uncontrolled soot burn can cause it. Unlike P24A0 the risk is thermal stress on the filter, so engines may cut the regeneration short.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.