P2450 – EVAP System Switching Valve Performance/Stuck Open

The switching valve sits in the evaporative system and either seals off part of it during the leak test or redirects flow; P2450 means the valve does not do its job or remains open. Ford calls it the vapor blocking valve: in 2020 to 2024 gasoline models the check runs in the third phase of the 0.040 inch cruise leak test, lasts 2 to 3 s and fails when a calculated ratio stays below 2.75 (Mode 6 test $3D, component $82). VW's 2014 Golf builds the valve into the leak detection pump and fails it when pump current differs from the reference by less than 3 mA. Bentley's V8 models of 2019 to 2021 point to the pump wiring, a smoke test and then the pump itself; Ford fixed P2450 on 2018 F-150s with a PCM update. The electrical faults of the same valve are P2418 to P2420; stuck closed is P2451.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.