P223E – O2 Sensor Reference Resistance Out Of Range (Bank 1)

P223E checks the internal resistance of the reference (Nernst) cell in the bank 1 wide-band sensor. That resistance falls as the ceramic heats up, so the ECM uses it as a thermometer; Bosch specifies 300 ohms nominal for the LSU 4.9 at operating temperature. GM's tables (2016-2019) convert the value supplied by the interface chip into an element temperature and flag anything below 700 °C or above 1,000 °C in 80 % of samples (64 of 80 in 2018, 128 of 160 in 2016/2019), starting 20 s after heater warm-up; the code is Type B. GM bulletin 16-NA-266 covers 2016-2017 ATS, CTS, CT6, Camaro, Malibu and Envision with the 2.0 turbo LTG: a voltage spike inside the ECM sets P223E or P0132 and also blocks remote start, cured by reprogramming. P223F is bank 2, P0135 the heater itself.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.