P2080 – Exhaust Gas Temperature Sensor Circuit Range/Performance (Bank 1 Sensor 1)
P2080 means the first exhaust temperature sensor on bank 1 passes its wiring checks, yet its reading does not fit the engine state. Each maker tests this differently. On the 6.6 L Duramax (GM 15OBDG09) the heat the exhaust flow should bring to the sensor is integrated and compared with what the sensor saw; the 3.0 L LZO (25OBDG04B) expects a minimum rise after more than 10,800 s of soak, which exposes a frozen value or a sensor no longer inside the pipe. Both are Type B. Ford's 6.7 L diesel cross-checks four sensors after 6 h off with a 50 °C key-on limit. VW's 2014 Touareg TDI allows 250 K above or 200 K below its model. Nissan cured false P2080 on the VK56VD and VR30DDTT petrol engines with new ECM software. Erratic jumps belong to P2081.
Possible causes
- Sensor element drifted or slow after many heat cycles
- Sensor loose, bent or not reaching into the exhaust stream
- ECM calibration flags a good sensor (software update released, e.g. Nissan)
- Exhaust leak upstream of the sensor cools the reading
Possible symptoms
- Engine warning lamp on
- Particulate filter regeneration blocked or aborted on diesels
- Often no noticeable change in driving
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.