P0D65 – Hybrid/EV Battery Pack Cooling Fan Enable Circuit Low

P0D65 reports a short to ground on the enable output of the battery cooling fan: the line stays low even though the controller is trying to switch the fan on. GM's 2013 eAssist mild hybrid table 13OBDG05C detects it from the output driver's fault flag for the power pack fan, 20 failures in 25 samples at 250 ms, Type B. The later hybrid tables 16OBDG02 to 19OBDG02 test it with the enable commanded on: a voltage under 5.35 V at system voltage above 10.2 V counts, and 16 failures in 20 samples set the code, again Type B with MIL after two trips. A chafed wire touching the body or a shorted input inside the fan are the usual finds. The fan cannot start, so expect higher battery temperatures and possibly reduced electric support. Open circuit is P0D64, short to voltage P0D66.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.