P0D46 – Battery Charger 14 Volt Output Voltage Sensor Circuit Intermittent/Erratic
P0D46 stands for a sporadic or unstable signal from the voltage sensor at the 14 V output of the on-board charger. No manufacturer documents it publicly. GM monitors this output in the Volt and ELR charger only for plausibility, low and high readings (P0D43-P0D45) and lists no intermittent variant. The Ford patent on a DC/DC stage housed in the charger shows why the value matters: that stage can regulate the 12 V bus during charging without closing the main contactors, and it needs a steady voltage feedback to do so. CARB counts erratic readings among the faults that comprehensive component monitoring has to catch. Loose low-voltage connections at the charger or a failing internal sense circuit are the main suspects.
Possible causes
- Loose 12 V, ground or signal connection at the charger
- Voltage sense circuit inside the charger failing intermittently
- Electrical interference on the low-voltage network
Possible symptoms
- 12 V battery not kept charged while plugged in
- Occasional charging interruptions
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search