P0D00 – Control Pilot Charging Ventilation Switch Circuit/Open
Some battery types can give off gases while charging; for that case the conductive charging standards provide a state in which the vehicle asks the station for ventilation. The vehicle signals it by switching a much smaller resistor of about 270 Ω onto the pilot, which drags the level to around 3 V; the station then only delivers power where ventilation is assured. P0D00 reports that the control circuit of this ventilation switch is open. No manufacturer documents this code publicly; GM's Chevrolet Volt monitors the switch for plausibility only (P0D01, normalized pilot voltage 0.04-0.10 in a self-test), and CARB requires plug-in vehicles to monitor the charging system. During normal charging the switch stays open, so an open circuit often goes unnoticed except for the stored code. Shorts are P0D02/P0D03.
Possible causes
- Open control wire or loose connector of the ventilation switch circuit
- Ventilation switch or its resistor branch open inside the module
- Failed driver stage in the charging control module
Possible symptoms
- Stored code, charging usually still works
- Charging system warning in the cluster
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.