P0CFB – Control Pilot Charging Switch A Circuit High
P0CFB is the high-side counterpart: the control or feedback line of charging switch A, which loads the pilot with an extra 1.3 kΩ to request charging, shows a voltage above its valid band. Typical are a short to a supply voltage in the harness or connector, or an output stage in the charging module that no longer pulls the line down. No manufacturer documents this code publicly; the closest documented test is GM's P0CF9 on the Chevrolet Volt, which judges the switch by the pilot voltage it produces in a self-test (ratio 0.14-0.28), while CARB requires plug-in vehicles to monitor the charging system. Low readings are P0CFA, an open line P0CF8, dropouts P0CFC. For the driver the station typically stays in the plugged-in state without supplying power, or a session cannot be ended cleanly.
Possible causes
- Switch control or feedback wire shorted to a supply voltage
- Output stage in the charging module no longer switching to ground
- Lost ground at the switch letting the line float high
Possible symptoms
- Vehicle detected at the station but no energy flows
- Charging cannot be stopped normally
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.