P0CE9 – Hybrid/EV Electronics Coolant Pump A Control Circuit/Open

The hybrid controller checks the control line of the electric pump that moves coolant through the power electronics loop, which in GM's Volt and ELR serves the inverter module and the high-voltage charger. GM tables from 2011 to 2016 fail it when the output driver reports an open line or a short to ground or voltage in 16 of 20 samples at 250 ms. The 2019 HPC2 table measures line current instead: below 200 mA or above 3 A while the pump is commanded on, below 120 µA while it is off, for 4 s within a 5 s window. All variants are Type B, two trips. Audi logs P0CE900 on the e-tron and Q8 e-tron in thermal management unit 00C5. P0CEB and P0CEC split the fault into low and high, P0CEA covers pump function. With the pump idle, inverter and charger heat up and power is reduced.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.