P0C67 – Generator Position Sensor Circuit A High
With P0C67 the controller sees circuit A of the generator resolver stuck above its upper limit. On the 2023 Outlander PHEV Mitsubishi assigns it to the sine winding and trips it once that voltage stays at or above 4.900 V for 0.21 s; the check runs continuously while the generator control unit has 8 V or more. Note the uneven window, since the lower limit is 2.0 V. A lead shorted to a supply potential is the textbook cause, and depending on the input stage an open line can also float high. The Bosch patent on resolver short detection separates both short types by the averaged line potential. Mitsubishi's repair path matches P0C66 and ends with a new power drive unit or generator. P0C6C is the matching cosine code.
Possible causes
- Sine lead of the resolver shorted to a supply or excitation potential
- Open sine lead that floats high at the input stage
- Faulty resolver input in the power drive unit
- Insulation fault between windings inside the resolver
Possible symptoms
- Malfunction indicator lamp and hybrid warning
- Engine-driven charging stops, battery charge falls faster
- Power limitation or hybrid functions switched off
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.