P0C28 – Electric/Auxiliary Transmission Fluid Pump A Motor Current High
P0C28 is the overcurrent protection of auxiliary pump motor A. GM uses it on Volt, ELR and later hybrids: the inverter trips when any of the U, V or W phases exceeds 35 A, in 2016 within about 4 ms of a 62 ms window, or when the d-axis current falls below a stator temperature limit, Type A, MIL on the first trip. GM service update 18199 for the 2018 Cadillac CT6 plug-in traces P0C28 to a faulty pump restart logic in the software. Ford's TSB 18-2282 lists P0C27 and/or P0C28 on the 2013-17 Fusion Energi and C-Max Energi, fixed by reprogramming the PCM and hybrid module; Ford also reports P0C28 in the SOBDMC of the 2024-25 Mustang Mach-E LFP, solved by software. P0C27 is the low side.
Possible causes
- Pump control software faulty (Cadillac CT6 update 18199, Ford Energi TSB 18-2282)
- Pump seized, contaminated or running against blocked flow
- Short between motor phases or to ground
- Current sensing or power stage in the pump inverter faulty
Possible symptoms
- MIL or service wrench lamp
- Auxiliary pump shuts down, no auto-stop or electric mode
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.