P0BB6 – Hybrid/EV Battery Voltage Sense Y Circuit High

The battery controller logs P0BB6 when the Y channel climbs above a level no healthy cell reaches. GM's first Volt of 2011 put that limit at 4.8 V or more, 1.4 s within 2 s, with the MIL after one trip. The 16OBDG02 programme samples every 100 ms and fails above 4.90 V in 14 of 18 samples, Type A; the eAssist battery fails above 4.65 V in seven of ten samples at 200 ms, Type B. A wiring fault that connects the Y input to the potential of the next cell is the most common explanation, followed by a failed input. Overcharging of a single cell is possible after a balancing problem and must be ruled out before the pack is charged again.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes