P0B98 – Hybrid/EV Battery Voltage Sense S Circuit High

P0B98 marks a sense S value that is too high to be a cell voltage. The thresholds vary with the battery chemistry and controller: GM's 2016 Volt and 2019 battery controllers flag 4.8 V or more after 1.4 s in 2 s (Type A), the 16OBDG02 programme 4.90 V in 14 of 18 samples (Type A), and the eAssist mild hybrid more than 4.65 V in 7 of 10 samples with the 12 V supply above 8.8 V (Type B). On the 2012 two-mode trucks S is NiMH block 19 and its limit is 23 V, 15 of 20 samples, Type B. Like the low test, the high test waits until open sense line faults are ruled out. The fix is usually wiring or the monitoring board; a truly overcharged cell is rare but must be excluded.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.