P0B89 – Hybrid/EV Battery Voltage Sense P Circuit High

P0B89 covers the opposite case to P0B88: the voltage reported on channel P is above the plausible range. GM's 2012 two-mode hybrids assign P to NiMH block 16 and set the code when the block exceeds 23 V in 15 of 20 samples at 100 ms, Type B, provided no battery controller fault P0A1F is active. In lithium-ion systems GM sets 4.8 V or more for 1.4 s in 2 s as the limit, Type A, while the BAS Plus mild hybrid reacts above 4.65 V. GM's 2016 program with a separate sense module allows up to 4.90 V. Overcharging is unlikely to be the cause because the controller stops charging well below these values; a sense lead reaching a higher tap or an input fault is the usual explanation. Expect restricted charging.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.