P0B52 – Hybrid/EV Battery Voltage Sense E Circuit High
The threshold behind P0B52 is chosen so that only a measurement error can reach it. A lithium-ion cell is fully charged at roughly 4.2 V, yet GM's battery energy control module waits for 4.8 V or more on channel E, for 1.4 s within 2 s, before storing the code as Type A, one trip. On the nickel-metal hydride packs of the 2012 two-mode trucks and SUVs the corresponding limit is 23 V for block 5, confirmed in 15 of 20 samples and stored as Type B. Since a false high reading could make the controller stop charging early or misjudge balancing, power and charging are restricted. Real overvoltage of a cell is reported by its own cell voltage codes.
Possible causes
- Channel E sense line contacting a higher cell tap
- Faulty measuring input or reference in the monitoring module
Possible symptoms
- Charging stops early or is refused
- MIL and reduced battery power
- Shorter electric range
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.