P0B43 – Hybrid/EV Battery Voltage Sense B Circuit High
P0B43 sets when cell voltage channel B reads higher than a lithium-ion cell can physically reach in service, so the controller blames the measurement path. GM documents the criteria for its battery energy control module: cell voltage B at 4.8 V or above for 1.4 s within a 2 s window, Type A, one trip, with open sense line, communication and balancing faults ruled out first. Beyond GM, no manufacturer documents P0B43 publicly; FCA's sister code P0B3E for channel A shows that software in the battery controller can cause such readings. CARB treats battery voltage sensors as monitored input components. Overcharged cells use separate cell voltage codes. Low, range and open faults of channel B are P0B42, P0B41 and P0B40.
Possible causes
- Open sense line letting the input float high
- Battery controller software misreading the channel
- Measurement input of the cell monitoring chip failed
Possible symptoms
- MIL and hybrid warning on
- Charging or electric drive limited
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.