P0B25 – Hybrid/EV Battery A Voltage Low

P0B25 sets when the voltage of hybrid/EV battery A drops below the window the controller expects. Bentley uses it in two different systems. In the 48 V Bentley Dynamic Ride anti-roll system it is stored in address 0021 (battery energy control module 2); if the highest and lowest cell readings differ by 0.5 V or more, an internal fault of the super capacitor is assumed and it is replaced. On the Bentayga and Flying Spur Hybrid the code appears in 008C, the high-voltage battery manager, with MIL and red battery warning, and the workshop must involve Bentley product support. GM checks pack undervoltage analogously with P0ABC (below 24 V). Unstable and high readings are P0B24 and P0B26. The driver loses roll control or battery power.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.