P0ADB – Hybrid/EV Battery Positive Contactor Control Circuit Low

P0ADB means the drive circuit of the positive main contactor reads too low, mostly a short to ground. GM uses it widely: 2016-19 tables set it when the control voltage stays under 5.35 V with the contactor commanded on, 13 of 16 samples, Type B. The 2013 eAssist battery controller checks the low-side driver in the off state for a short to ground or an open circuit, 3 of 5 samples, two trips. Audi lists P0ADB00 in battery management 2 (J1120) of 2019-22 A6 to Q8 models with a software fix (TSB 2066205), and Dodge names it for the 2024 Charger EV (TSB 08-071-25). The battery then cannot be connected, so the vehicle will not become ready.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.