P0A67 – Drive Motor B Phase U Current Low
P0A67 reports that phase U of drive motor B carries too little current at the moment it should peak, which GM interprets as an open circuit in that phase. In the 2016 Chevrolet Volt tables for motor control processor B the test runs while the rotor is within 30 degrees of the U axis, the inverter is above 50 V in normal PWM and the squared current command exceeds 900 A²; a peak below 9 A for 0.4 s within a 0.6 s window sets a Type A fault with MIL on the first trip. GM's 2018 tables shared by the Volt and the CT6 plug-in keep the test but raise the command threshold to 4,900 A². P0A68 is the high side, P0A6A and P0A6D are phases V and W, P0A5E the motor A counterpart. Motor B is disabled.
Possible causes
- Open circuit in the phase U cable, connector or terminal of motor B
- Phase U switch of the motor B inverter not conducting
- Phase U current sensor stuck at zero
- Open winding of phase U in drive motor B
Possible symptoms
- MIL on the first trip and propulsion system warning
- Jerky or weak electric drive, reduced power
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.