P0A64 – Drive Motor A Phase W Current Low
P0A64 means phase W of drive motor A shows too little current at the moment it should peak, typically an open W lead or a W sensor stuck at zero. GM completes its three-phase sequence with this code on the 2016 Chevrolet Volt motor control processor and in the 2018 hybrid tables: when the rotor sits within 30 degrees of the W phase axis, the inverter runs normal PWM above 50 V and the squared current command exceeds 900 A2 (2016) or 4,900 A2 (2018), a W peak below 9 A for 0.4 s of a 0.6 s window sets P0A64 as Type A, MIL on the first trip. Because the rotor passes each axis in turn, only the open phase is flagged. A Caterpillar patent uses a near-zero phase reading the same way. P0A65 is the high side, P0A5E and P0A61 cover U and V.
Possible causes
- Open circuit in the phase W cable, connector or terminal
- Phase W current sensor reads zero
- Phase W switch of the inverter not conducting
- Open winding of phase W in drive motor A
Possible symptoms
- MIL and propulsion system warning
- Uneven or reduced electric drive torque
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.