P0A3F – Drive Motor A Position Sensor Circuit
The rotor position of a traction motor is read by a resolver: one excitation coil and two pickup coils that return sine and cosine signals. P0A3F is the basic circuit code for motor A and mostly means the signal is gone. GM sets it when the sine or cosine amplitude drops below 2.3 V (Type A, one trip in the 2011 and 2016 tables); Mitsubishi (2023 Outlander PHEV front motor) watches the excitation voltage and fails it outside 1.0 to 2.86 V for 0.14 s. Field causes: a spread terminal at the X2 connector of the Chevrolet Bolt, low 12 V supply on the 2014 Subaru XV Crosstrek Hybrid (software fix), Stellantis Pacifica Hybrid. P0A40 covers a degraded signal. Expect lost propulsion or no electric drive.
Possible causes
- Spread or poorly seated terminal at the resolver connector (documented on the Chevrolet Bolt)
- Open or shorted excitation, sine or cosine wire between motor and inverter
- Low 12 V auxiliary battery voltage disturbing the motor control module (Subaru, fixed by reprogramming)
- Resolver coil failed inside the motor
- Faulty resolver excitation or input stage in the inverter/motor control module
Possible symptoms
- Sudden loss of propulsion, sometimes normal again after a restart
- MIL and hybrid/EV system warning on
- Vehicle will not enter ready mode or electric drive is disabled
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.