P0716 – Input/Turbine Shaft Speed Sensor A Circuit Range/Performance
The input or turbine shaft speed sensor – a Hall sensor with square-wave output or an inductive sensor with sine output – reports the speed behind the torque converter. With output and engine speed it gives the actual gear ratio, converter slip and shift timing. P0716 means a signal is present but implausible: too high, or dropping suddenly without recovering. GM's 2025 modules count drops of more than 650 rpm between 25 ms samples and fail after more than three; the 6T70 in the Saab 9-4X flags a 1350 rpm drop for 1 s; the 2007 Allison 1000 also detects noise and swapped sensor wires; all after one trip. Ford's 6R80 flags turbine speed above 7700 rpm. The 6T70 then runs only reverse and fifth gear, with maximum line pressure and no converter clutch.
Possible causes
- Loose contact or chafing in the sensor circuit
- Sensor faulty, wrong air gap or metal debris
- Reluctor wheel or clutch drum damaged
- Sensor wires swapped after repair or interference
Possible symptoms
- Check engine and/or transmission warning lamp
- Limp mode with fixed gear (6T70: reverse and fifth only)
- Harsh or delayed shifts
- Torque converter clutch locked out
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.