P049B – EGR B Flow Insufficient Detected
Exhaust gas recirculation (EGR) routes part of the exhaust back into the intake to lower combustion temperature and NOx. Circuit B is the second EGR path; on diesels with two circuits it is the low-pressure EGR, which takes exhaust after the particulate filter and feeds it in before the turbo compressor (GM diesels 2016–18, FCA's 2.2 and 3.0 diesels). P049B means too little flow in circuit B: with the low-pressure valve open the module expects a change in fresh air mass or manifold pressure, or a modelled EGR volume, and the actual flow stays below the threshold. FCA documents it on the 3.0-litre EcoDiesel third generation in the 2020 Ram 1500, partly as a false trigger fixed by a software update; thresholds are not published.
Possible causes
- Software or calibration (false trigger)
- Low-pressure EGR valve sooted or stuck closed
- Low-pressure EGR cooler or line blocked
- Implausible sensors (air mass, pressure difference)
Possible symptoms
- Check engine light on
- Sluggish acceleration (FCA bulletin)
- Higher NOx
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.