P0489 – EGR A Control Circuit Low

Exhaust gas recirculation (EGR) routes part of the exhaust back into the intake to lower combustion temperature and NOx. P0489 means the drive circuit of EGR valve A – solenoid, stepper or DC motor – is shorted to ground. GM's Duramax LML sets it at 0.5 Ω or less to ground for 3 s, GM's 2016 diesels after 96 of 120 samples, Ford diesels after 0.35 s, Saab's 2.0 TiD likewise – MIL after two trips. The valve is usually switched off; with low-side control a short to ground can keep it energised and open, causing rough idle or stalling.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.