P0454 – EVAP System Pressure Sensor/Switch A Circuit Intermittent

The evaporative emission (EVAP) system stores fuel vapour from the tank in a charcoal canister; a purge valve lets the engine draw it off, and a vent valve opens the canister to fresh air. The tank pressure sensor measures small pressures around ambient for the leak tests. Its direction differs by maker – on GM vacuum raises the voltage, on Ford and Bosch pressure does – so low and high refer to the signal voltage only. P0454 means the signal jumps. Ford checks continuously for a jump above about 1 kPa between two samples 100 ms apart or a brief open or short. GM (and the Saab 9-4X) checks only during the engine-off leak test: a jump of about 112 Pa within 1 s that refuelling cannot explain, 2 of 3 tests, MIL on the first trip. Saab's ME9 does not use the code. The engine-off small-leak test is then discarded.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.