P0446 – EVAP System Vent Control Circuit

The evaporative emission (EVAP) system stores fuel vapour from the tank in a charcoal canister; a purge valve lets the engine draw it off, and a vent valve opens the canister to fresh air. The vent valve is normally open and closes for the leak test. By its wording P0446 is its control circuit, and Ford uses it that way for open and shorted circuits. GM, however, uses P0446 for vent system performance – a blocked vent path: while purging with the vent valve open, the tank must not build up vacuum; more than 2989 Pa for 5 s before 4 litres have been purged sets the code, MIL after two trips. GM reports vent circuit faults as P0449, P0498 and P0499. A blocked vent makes refuelling difficult.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.