P043F – EVAP System Leak Detection Reference Orifice High Flow
The evaporative emission (EVAP) system stores fuel vapour from the tank in a charcoal canister; a purge valve lets the engine draw it off, and a vent valve opens the canister to fresh air. Systems with a leak detection pump (Bosch DM-TL at VW, Audi, BMW and Maserati, Denso's canister pump module at Toyota/Lexus) first measure a reference value with the pump working only through a built-in 0.5 mm (0.020 in) orifice; it is the yardstick for the small-leak test that CARB requires. P043F means the reference measurement shows too much flow – the reference vacuum or pressure does not reach the expected value, because the reference path or changeover valve leaks, the pump is weak, or air enters through leaking valves in the test path. The leak test can then not be judged, since a weak yardstick would hide leaks. GM and Ford do not use the code.
Possible causes
- Leak detection pump faulty (weak pump, leaking changeover valve, liquid damage)
- Purge valve does not seal
- Pump supply or connector (contact resistance, corrosion)
- Leaking hose between pump module and canister
Possible symptoms
- Check engine light on
- EVAP leak test does not run, readiness not set
- Usually no change in driving
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.