P0230 – Fuel Pump Primary Circuit
The fuel pump circuit has two sides: the primary circuit is the engine module's output to the fuel pump relay coil (or to a pump control module), the secondary circuit is the power circuit from relay contact or module to the pump itself. P0230 concerns the primary side. GM's output driver compares the commanded with the actual state of the relay control circuit and sets the code at 8 of 10 mismatches, after two trips; Ford checks for open or short circuits for 2–5 s. With a failed relay control the pump stays off and the engine will not start or dies; a short to voltage keeps the pump running and drains the battery. On Ford systems with a pump control module the code means its power relay circuit; on the Subaru-based Saab 9-2X it is the pump module's collective fault report.
Possible causes
- Fuel pump relay faulty (coil open or shorted)
- Control wire from module to relay open or shorted to ground or voltage
- Relay supply, ground or fuse missing
- With a pump control module: its supply, ground or the module itself
- Engine module driver faulty
Possible symptoms
- Engine cranks but does not start
- Engine stalls while driving
- Check engine light on
- No pump prime noise at ignition on; with a short to voltage the pump runs on and drains the battery
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search
Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.