P0155 – O2 Sensor Heater Circuit Bank 2 Sensor 1

The upstream oxygen sensor on bank 2 (sensor 1) has its own electric heater. P0155 is the bank 2 counterpart of P0135: the heater current is outside its window or the driver voltage does not follow the command. GM fails it outside 0.3–3.1 A (8 s or 8 of 10 samples, two trips); Ford outside roughly 0.22–0.465 A minimum to 3 A, with related codes for heater temperature control (P0050) and resistance (P0059). Closed loop on bank 2 then starts late after a cold start, and the sensor checks are suspended. P0135 together with P0155 points to a shared supply or fuse.

Possible causes

Possible symptoms

Diagnosis

Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.

Related DTC codes

Search this code in DTC Search

Generic OBD-II reference only. Manufacturer-specific definitions, test values and repair procedures can vary by vehicle. Verify with vehicle-specific service information.