P0145 – O2 Sensor Circuit Slow Response Bank 1 Sensor 3
Sensor 3 is a third oxygen sensor on bank 1, behind a second converter or converter brick. It only exists on some vehicles – documented for Jaguar Land Rover's 3.0 V6 supercharged (2013–2016, where sensor 2 is 'mid-cat' and sensor 3 'post-cat') and Ford systems that monitor part of the converter volume. P0145 means sensor 3 reacts too slowly to mixture changes, typically measured around fuel cut-off as for sensor 2 (P0139). No manufacturer document using exactly this code was found – Jaguar Land Rover, the only documented user of sensor 3, does not list it. The description rests on CARB's response-rate requirement for downstream sensors and on the sensor 2 test logic. When it fails, the control module stops the downstream trim and cannot evaluate the converter; there is no limp mode.
Possible causes
- Sensor aged or contaminated (oil ash, silicone, additives)
- Exhaust leak ahead of the sensor
- Sensor heater weak, sensor too cold
Possible symptoms
- Check engine light on (usually after two drive cycles)
- Usually no noticeable change in driving
Diagnosis
Use a compatible scan tool to confirm the code and check related codes and live data. Inspect the relevant wiring, connectors, power, ground and sensor signals using the vehicle manufacturer’s wiring diagram and service specifications. Do not replace a component based on the code alone.
Related DTC codes
Search this code in DTC Search